Clarke ENCORE MAX Manual do Operador Página 60

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 59
1-60 CLARKE
ENCORE MAX
TRIO SCRUBBER DIAGNOSTIC CODES CON’T.
Dependent on programming. Recharge batteries immediately.
Possible controller fault. Replace controller if not cleared by disconnecting
batteries for 1 minute.
Throttle in drive position during Incorrect operation of machine. Otherwise, check
switch on. throttle mechanism condition; all wiring on
machine for short circuits or breaks (including
Trio 20-way, LCD 16-way if used, front panel
switches & controls); actual switches & controls.
All 310x codes - probable short Check the Traction, Brush & Vac motor
circuit of output device or wiring- connections on Trio; check wiring from these
can sometimes cause perman- connections down to the motors, also checking
nent Controller fault. wiring all along the way for proper connections
and short circuits. Check for the same on Trio’s
14-way connector, as well as the wiring else
where on the rest of machine. Otherwise, replace
controller.
Possible Controller fault. Replace controller if not cleared by disconnecting
batteries for 1 minute.
Possible Controller fault. Replace controller if not cleared by disconnecting
batteries for 1 minute.
Check wiring for short circuits on Trio’s 20-way
All 70xx codes-Check wiring of connector, the LCD’s 16-way connector (if used)
brake & freewheel switch & wiring to freewheel switch & switch itself. Check
traction motor connection on Trio & wiring from
this connector down to electromagnectic brake on
traction motor, checking connections all the way.
Can be caused by excessive pushing or rolling
down an incline or incorrect operation of machine
Wiring fault on 6-way serial link Check wiring & connections on both Trio & LCD
between Trio & LCD. 6-way connectors.
LCD memory corrupt Disconnect batteries & wait 1 minute before
reapplying power.
Open circuit on brush motors or Check brush motor connection to Trio & wiring
brush motor wiring from this connector down to brush motor, check-
ing connections all the way. Otherwise, possible
brush motor fault.
Soft battery lockout
occurred
No output drive
Tiller displace error
Bridge fault 1
Traction bridge fault
Brush/Vac bridge
fault
Soft waiting for
bridge to charge
Traction bridge
fault 2
Bridge fault 2
Minefield mismatch
No internal timers
Internal timer out
of range
A to D readings not
finished before next
read
Unknown mux
channel
ADC module not
ready error
Test trip latch 1
Test trip latch 2
Test trip latch 3
Test trip latch 8
Test trip latch 9
Test trip latch 10
Test trip latch 11
Test trip latch 12
Test trip latch 13
Test trip latch 14
Startup with push
activiated
Push activated in
drive mode
CODE PGDT TECHNICAL PROBABLE CAUSE SERVICE ACTION
DESCRIPTION
LCD module
communications
timeout
LCD module settings
corrupt
Soft brush motor
disconnected error
Vista de página 59
1 2 ... 55 56 57 58 59 60 61

Comentários a estes Manuais

Sem comentários