Clarke FG2000 Especificações Página 10

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 9
10
Wiring instructions for the Clark Reliance GL53 Illuminators
(for 'C' and 'S' Series Gages).
Note: Make sure that the power is turned off to the supply wiring
before connecting the illuminator.
Tools needed:
Slotted Screwdriver
1/2" Wrench
1. Open the illuminator housing by loosening the three hex head cap
screws on the end of the unit that secures the Conduit/Lamp
assembly in place.
2. Carefully remove the assembly and remove the 60W Frosted
Lamp (B) from the illuminator housing and set aside.
3. Loosen the screw (C) from the side of the lamp socket/conduit
connector that holds the assembly in place on the pipe nipple.
4. Take the lamp socket/conduit connector assembly (D) off of the
housing end piece and set the housing aside.
5. Disassemble the lamp socket/conduit connection assembly by
removing the two screws (E) from inside of the lamp socket. (Note
that there are two small washers on the assembly screws. Do not
lose these washers as they are needed for re-assembling the
illuminator.)
7. Connect the black wire to the gold screw terminal on the bottom
of the lamp socket.
8. Connect the white wire to the silverscrew terminal on the bottom
of the lamp socket.
9. Re-assemble the lamp socket/conduit connector assembly using
the same two screws with washers inside of the lamp socket. Make
sure that the mounting plate is centered on the lamp socket/conduit
connector assembly.
10. Thread the lamp socket/conduit connector assembly back into
the bottom of the pipe nipple and tighten the holding screw.
11. Carefully screw the lamp into the socket and re-assemble the
bottom assembly back onto the illuminator housing (make sure that
the gasket between the bottom assembly and housing is in place).
Secure by tightening the three hex head cap screws on the bottom
side of the housing.
12. Wire the illuminator to the 120 V.* power supply. (*Unless lamp is
for 230 V. service) Note that a proper ground wire is recommended.
GL53 Illuminator - 120V.
Specification:60W/120V
Current Draw: .5 Amps
Vista de página 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 16

Comentários a estes Manuais

Sem comentários